Every scientist goal is to analyze target compounds, quickly and reliably within a given time and budget. The ChroZen UHPLC System satisfies both productivity and efficiency by producing the results 4-10 times faster than conventional HPLC’s while ensuring both superior sensitivity and resolution.
The Chozen UPLC System is designed to withstand real ultra-high pressure up to 18,800 psi (1,300 bar). The powerful pump technology provides an accurate and precise flow rate by applying the concept of linear drive technology into two pairs of serially coupled pump heads, this results in the end-user being able to fully utilize the UHPLC columns and have reliable data.
- Benefits
-
Resolution
&
Sensitivity - Specifications
- Demo
- Quote
- Downloads
Benefits
- 4-10 times faster than traditional HPLC
Greater Efficiency
- Low flow rates injection minimizing solvent and sample usage
Remarkable Resolution & Sensitivity
- Total Reflection Cell with Liquid Core Waveguide Technology enhancing resolution
- Reduced system dead volume giving improved sensitivity
Reliability
- Automatic compressibility compensation providing accurate control for more stable gradients
Maximize UHPLC Columns
- Ultra-high pressure, up to 18,800 psi, utilizes the lifetime of UHPLC column
Resolution & Sensitivity
To support this, the ChroZen UHPLC mechanically minimizes
system dispersion by utilizing a low internal volume with a Total Reflection Cell and applying the Liquid Core Waveguide technology which all reduces the loss of light source to maintain the intensity in optical clarity. Also, the extremely fast data acquisition rate of 125 Hz, enables rapid data processing for an enhanced effect on peak heights and width. Therefore, it produces a higher resolution and sensitivity.
Specifications
ChroZen UHPLC Pump | |
---|---|
Hydraulic system | Dual pistons in series pump with proprietary individual servo-controlled linear drive technology, featuring truly automatic compressibility compensation |
Flow range | 0.001 ~ 2.000 mL/min(Max. 5ml/min) |
Flow precision | ≤ 0.075 % RSD or 0.005 min SD, whichever is greater |
Flow accuracy | ± 1% or ± 10 μL/min, whichever is greater |
Maximum operating pressure | 18,800 psi(1300 bar) |
Solvent selection | 2 solvents per pump module (A/B) |
Delay volume | 50 μL when using 35 μL mixer / Optional mixer: 100μL, 150μL |
Integrated degassing unit | Integrated 2-channel degasser, with 480 μL chambers |
Communications | LAN |
ChroZen UHPLC UV/Vis Detector | |
---|---|
Maximum data rate | 125 Hz (single wavelength detection) |
Noise | <0.5 x 10-5 AU, at 254 nm (single wavelength detection) |
Linearity | >2.0 AU upper limit |
Wavelength range | 190 ~ 900 nm |
Wavelength accuracy | ±1 nm, self-calibration with deuterium lines, verification with holmium oxide filter |
Wavelength precision | <±0.1 nm |
Flow cells | Standard: 2.4 μL volume, 10 mm cell path length and 1,000 psi Pressure maximum |
Communication | LAN |
ChroZen UHPLC PDA Detector | |
---|---|
No. of PDA channel | 1024 |
Wavelength range | 190 ~ 950 nm |
Noise | < ± 0.7 x 10-5 AU (Empty cell, 2 sec Rinse time, 254 nm) |
Flow cell | Standard : 2.4 μL Volume, 10 mm cell path length and 1,000 psi pressure maximum |
ChroZen UHPLC Autosampler | |
---|---|
Injection range | Partial loopfill: 0 ~ 10 μL / Full loop /μL pick-up: not applicable |
Precision reproducibility (valid at 1.0 cP) | RSD < 0.5% for partial loopfill injections, injection volumes > 5 μL at constant pressure |
Pressure range | 0 ~ 18,800 psi (0 ~ 1300 bar) |
Sample capacity | 96 x 2 mL vial (two trays default) |
Carry over | 0.05% with programmable needle wash |
Communications | LAN |
ChroZen UHPLC Column Compartment | |
---|---|
Temperature range | 4 ~ 90℃ (Peltier cooling and heating) |
Temperature stability | 0.05℃ |
No. of columns | Max. 3 ea of 15 cm columns |
Communications | LAN |
Demo
Quote
Quote
- Downloads : ChroZen UHPLC Brochure ENG 2019
- Downloads : ChroZen UHPLC Residual-Pesticide 19-Kinds ENG
- Downloads : ChroZenUHPLC Preservative of Cosmetic Analysis (13 mix IS) -1
- Downloads : ChroZenUHPLC Preservative of Cosmetic Analysis (13 mix IS) -2
- Downloads : ChroZenUHPLC Saponin of Red ginseng Resin (Rg1 Rb1 Rg3) Analysis